Skip to main content

Advertisement

Springer Nature is making Coronavirus research free. View research | View latest news | Sign up for updates

Table 3 Effects of SSA of the particles on SAR value.

From: Size dependent heat generation of magnetite nanoparticles under AC magnetic field for cancer therapy

110 kHz     
Samples SAR (W/g) Slope
  2.5 kW 6.0 kW 13.1 kW  
A 2.08 16.25 42.60 3.85
B 1.75 16.32 59.30 5.58
C 6.19 25.10 57.08 4.81
D 12.84 40.80 69.21 5.18
E 14.18 40.35 67.82 4.94
F 13.66 29.17 41.16 2.49
G 12.86 22.44 29.03 1.45
H 6.08 8.87 12.77 0.63
I 8.14 13.85 18.16 0.91
J 6.28 10.95 15.37 0.83
K 3.73 8.11 9.78 0.53
L 2.44 4.57 6.54 0.37
M -0.20 2.27 4.46 0.42
200 kHz     
Samples SAR (W/g) Slope
  2.5 kW 6.0 kW 13.0 kW  
A 4.20 14.83 56.63 5.13
B 4.18 16.54 78.53 7.33
C 7.25 28.23 85.06 7.51
D 16.81 50.48 93.54 7.14
E 17.75 55.95 93.72 6.97
F 19.58 38.30 66.60 4.42
G 19.28 36.34 53.72 3.17
H 10.99 18.02 26.46 1.44
I 12.58 24.25 35.84 2.14
J 12.29 19.06 27.43 1.41
K 8.42 13.93 18.12 0.88
L 5.83 9.96 12.83 0.63
M 2.68 3.13 4.45 0.17
360 kHz     
Samples SAR (W/g) Slope
  1.6 kW 3.5 kW 5.2 kW  
A -0.59 -0.10 3.84 1.21
B 1.02 2.59 6.34 1.47
C 2.81 8.03 16.67 3.83
D 4.28 14.72 24.82 5.70
E 7.43 26.10 45.47 10.55
F 10.38 24.79 35.41 6.96
G 13.70 29.42 39.32 7.14
H 10.50 16.79 19.64 2.55
I 10.05 19.80 29.18 5.31
J 10.80 20.06 25.08 3.99
K 7.46 15.30 19.05 3.24
L 5.76 10.56 14.14 2.33
M 0.96 4.22 5.09 1.16
  1. Slopes represent the dependency of the AMF power to the SAR value. The experiments performed under the several AMF frequency and power.